Sometimes it can be a difficult task to remember about your last fire damper testing. A fire damper should be maintained and inspected regularly for its proper working in times of emergency. Fire dampers are installed for the prevention of smoke or fire in a building. They are installed in a duct where the duct combines with the barrier.
They operate using a heat-sensitive device that, when activated, melts causing the fire damper components to close. It contains an electric heat release device that gets closed in a more controlled way upon heating.
To guide you in maintaining a fire damper, we provide you with some simple steps-
Know the time-
It is important to know the time of a fire damper maintenance. A fire damper inspection should be carried out after every 4years in a commercial building. If the building is new or has been recently renovated, dampers should be inspected once a year. Delaying an inspection could result in a penalty.
See your last report- Having your previous report in hand will help to fasten up the present inspection. The previous report will show whether the fire/smoke dampers are new or which one had undergone repair and which one needs repairing. This will give you an idea of how long your inspection will last.
Life safety maps-
Life safety maps of the dampers will enhance your inspection. This will make the fire damper testing smoother and faster. When there are maps, the person exactly knows where to look for the repair and finishes the job on time. Without a map, one has to spend considerable time in maintenance.
Plan a schedule- Schedule your inspection in advance. Set a date and time of the schedule to make your inspection smoother and more efficient. This will let you know of other projects and organize accordingly.
Do the repairs- If any repair is required, go for it. According to NFPA 80, repairs should be done without any delay. The contractors have the replacement parts in hand that will save time in the inspection. This will make the process faster.
Documentation-
Proper documentation is required after the inspection is over. Documentation of the inspection should include the date and time of the inspection, how many dampers were repaired, how many were inspected, etc. This is proof that your fire damper had a proper and timely inspection.
Final words
Fire dampers must be regularly inspected by technicians according to NFPA80. Fire dampers testing must be carried out before the occupancy of the building. This will protect you and your building from any danger.